Specification
- Measurement range (relativ) up 1m WS.
0 - 0,1 bar to 0 - 25 bar or 1m to 250 m water output versions 4 -20 mA 2 wire 0 -10 V 0 - 5 V 0,5 - 4,5 V for handheld applications - operating condition
ambient operating temp.: +5°C bis 70°C protection mode: IP 68 to 250 m - electronic and housing
- supply voltage 12 - 30 V DC
- accuracy 12bit
- total error < 1,5% FS
medium contacted material: CR Ni steel or silicon (1bar ) mit NBR -O - ring all signals are calibrated and configurated with software special cable with pressure balance - dimension
diameter 22 mm Lenght 100 mm Gewicht 550 g - Options at enquiry
CAN - Bus CAN_open 2.0 A with Physical Layer at DIN 11898 Special cable lenght Customer specific connector Measurement of temperature |  | Applications Measurement in - water equipment
- wells till tepth of 250m
- connectable with DMT-119 (Datalogger)
|