Startseite | Level transmitter
PS1 Print
Specification

  • Measurement range (relativ) up 1m WS.
    0 - 0,1 bar to 0 - 25 bar
    or 1m to 250 m water
    output versions
    4 -20 mA 2 wire
    0 -10 V
    0 - 5 V
    0,5 - 4,5 V for handheld applications
  • operating condition
    ambient operating temp.: +5°C bis 70°C
    protection mode: IP 68 to 250 m
  • electronic and housing
  • supply voltage 12 - 30 V DC
  • accuracy 12bit
  • total error < 1,5% FS
    medium contacted material: CR Ni steel
    or silicon (1bar ) mit NBR -O - ring
    all signals are calibrated and configurated
    with software
    special cable with pressure balance
  • dimension
    diameter 22 mm
    Lenght 100 mm
    Gewicht 550 g
  • Options at enquiry
    CAN - Bus CAN_open 2.0 A
    with Physical Layer at DIN 11898
    Special cable lenght
    Customer specific connector
    Measurement of temperature

Level Transmitter PS1

Applications

Measurement in
  • water equipment
  • wells till tepth of 250m
  • connectable with DMT-119 (Datalogger)
Attachments:
 Pegelsonde PS1[deutsch]19 Kb
 level probe PS1[englisch]19 Kb