Small device for desiccation of buildings voltage supply: 24 V DC (plug-in power supply)
terminal for:
- indoor climatic (T, rF): VB = 5V, digital out
- outdoor climatic (T, rF): VB = 5V, digital out
- 1 Ventilator : 24 V DC / 12 W
- alternative 1 window opener: 24V DC / 15 W
Measurement range sensors:
- indoor: 0...100 % rF, 0...50 °C
- output: digital (rF, T)
- outdoor: 0...100 % rF, -40...+80 °C
- output: digital (rF, T)
- precision T: ± 0,2 °C
- precision rF: ± 2 %
Functions:
- humidity (absolute) automatic control with comparison aH Out > aH In
- programmable switching time of ventilation in area with: 1...99 min
Default: 10 min ON, 20 min OFF- integrated frost protection
- manual ventilation with keypress:
ventilation works immediately and finished automatic after 20 min or after the 2. keypressed- Datalogger and Data transfer to PC with USB-cable
scope of supply:
- device EKS-12,
- climatic sensor KS11 as plug-in (indoor),
- climatic sensor KS10 with 10 cablel (outdoor),
- manual
- plug-in power supply 24V
- PC-Software
|