Criteria Parameter - temperature range: -40...+80 °C
- accuracy: ±1,5 K (-40...+80 °C)
- technology: semiconductor
- Resolution: 10 Bit
- Scanning density: >= 5 ms
Protocol - CAN-Protocol: CANopen 2.0 A, by CiA DS 404
- Physical Layer: by ISO 11898
- Supply Voltage: 12 V ±20 %
Operating Conditions- ambient temperature: -40 °C bis +80 °C
- storage temperature: -40 °C bis +120 °C
- Shock strenght: 30 g, in 14 ms at RT
- Vibration stability: 10 g bei 20-1000 Hz
- EMV and ESD checked: EN 50082-1 und EN 50082-2
|  | Applications This temperature sensor enable the mearuring of temperature in water-hydraulic and other tubes under defined operation conditions - water control
- hydraulik tubes
- brake fluid tubes
- etc.
Electrical connection: 5-poliger Binder-connector M12x1 (male) by CiA DR-303-1
|