Publikationen CAN-BUS
Startseite | CAN-Bus | DS - CAN - 01
DS-CAN-01 Print
  
Criteria

Basis
  • Sensor cell based on a high-grade steel membrane piezoresistive bridgeconnection (without interlayer-medium) consisting Polysilizium
  • sensor signal processing integrated CMOS-Technology
  • medium compatible with hydraulic-oil, brake-fluid, gasoline, diesel, compressed air, etc.
  • pressure ranges
    - 2 to 4000 bar (Si of high grade steel)
    - -1 to 2 bar (Si)
Measurement types
  • relative pressure against ambient pressure or against internal atmosphere
Measuring parameters
  • measuring resolution: 10 Bit
  • total error band: < 1,5 % full scale, between -10...+80 °C
  • measuring step: as of 5 ms
Electrical port
  • CAN-protocol: CANopen 2.0 A
  • physical layer: acc. DIN 11898
Operating conditions
  • operating temperature: -10 °C to +80 °C
  • storage temperature -20 °C to +120 °C
  • shock proof 30 g duration 14 ms at RT
  • vibration stability 10g / 20-1000 Hz
  • CE- conformity in accordance with: EN 50082-1 and EN 50082-2

CAN-Bus pressure sensor DS-CAN-01

Applications

  • Hydraulic
  • Pneumatic
  • Environmental technology
  • Process control
  • Climatic systems
  • Semiconductor industry
  • Automotiv
  • Agricultural devices
  • Heating systems
  • Robot systems

  1. Standard ranges in kPa (other ranges on inquiry)
    0-500
    0-1.000
    0-2.000
    0-5.000
    0-10.000
    0-35.000
    0-50.000
    0-70.000
    0-200.000
    0-400.000
  2. All parts that get in contact with the media are made of following materials
    - to 500 bar X 5 CrNi1810 SUS 304 - 50 Mpa
    - to 2000 bar X 5 CrNiCuNb 174 SUS 630 - 100 Mpa
    no 0-rings and silicon oil pattern